| We use this system
in conditions where driven piles are unsuitable such as in cases of
settlement related to clay shrinkage or for tension piles in a cantilever
beam system.
To install these piles M&D Foundations and Building
Services Ltd. use a special track-mounted mini-pile assembly which
can be operated inside domestic properties and in locations where
headroom is as low as 2.4 metres.
We offer piles ranging from 100mm - 300mm in diameter.
Safe working loads are established dependent on the nature of the
bearing strata, into which piles are founded.
This type of drilling rig can also easily be adapted
for down the hole hammer drilling to enable anchorage into firm
strata such as mud stone, sandstone, etc.
- Height :
2200mm
- Weight :
1500kg
- Min width
: 720mm
- Max width
: 1000mm
- Pile size
: 150mm - 300mm
- Tracks :
Rubber
|